Leave a message
The installation of the traction electromagnet must be strictly followed to ensure safety and efficiency. First, select a flat, sturdy, and rust-free metal surface as the installation location, ensuring it can withstand the electromagnet's load (e.g., rated suction force ≥ 500 kg). Second, use high-strength screws (e.g., M10 specification) to secure the mounting base, ensuring no looseness or wobbling to maintain stability. When connecting the circuit, the power supply voltage (e.g., AC 220V ± 10%) must match the electromagnet's rated parameters to avoid overload or voltage imbalance. During the commissioning phase, monitor the current (e.g., 2-3A), suction force, and abnormal vibrations; if any problems are found, immediately stop the machine and investigate.